![]() ![]() Make sure the Traffic, TC Comms, Loop, 15 Vdc, 12Vdc, and 24Vdc LEDs are lit.Inspect the cable from PSUP(P17) to I/O PCB (P56), pull on each wire to make sure the pin is correctly locked in the housing.Check the 3-Phase power input from PSUP(P4) to I/O PCB (P55).To test the cable refer to Network Cable Tester Tool procedure. Check the RJ-45cable connection from Maincon PCB (J14) to I/O PCB (J4).The I/O PCB board lost communications with the Maincon PCB. Multiple Alarms or 9924 CONTROL AND IO BOARD COMMUNICATION LOST 9925 CONTROL AND IO BOARD COMMUNICATION DID NOT INITIALIZE and all the input values on the diagnostic page show XX. Reload the I/O PCB main firmware refer to Next Generation Control - I/O PCB Main Firmware - Update. The firmware update failed, or I/O firmware is corrupted. The Main CRC and the Factory CRC are now the same.Īlarm 9933 SOFTWARE VERSION MISMATCH and 9100 If the alarm does not clear, cycle the machine power. Go to I/O Config in the Diagnostics tab.Note: The USB memory device must contain your Haas Control Key and the correct configuration files. Put the USB memory device into the control.Main CRC and Factory CRC do not match due to the I/O PCB being swapped out. ![]() Alarm 9100 NON RESETTABLE SOFTWARE ERROR at Power On, or Alarm 9915 IO BOARD CONFIGURATION MISMATCH. ![]()